Intended use:
Principle:
Main components:
No. | Components |
BIK-QL-H0019S1
|
1 |
PCR Enzyme Mix
(Lyophilized)
|
24 tests/kit
|
2 |
Positive Control
|
100 μL/tube
|
3 |
Negative Control
|
100 μL/tube
|
4 |
RNase-free water
|
1mL/tube
|
5 |
Paraffin oil
|
1.5mL/tube
|
Specimen requirements:
1. Specimen type
Urine or urethral swabs for men, and female urine, cervical swabs, or vaginal swab samples
2. Specimen Preservation
The specimen can be stored for 3 months at -20±5℃ and for a long time below -70℃
PCR Amplification condition:
PCR amplification according to the following procedures:
Step | Cycle number | Temperature | Time |
1 | 1 | 95℃ | 3min |
2 | 40 | 95℃ | 10s |
60℃ | 30s collect fluorescent |
Instrument detection channel selection: FAM and HEX/VIC.
Quality control:
Ct value | |
Negative Control | No Ct |
Positive Control | ≤30 |
IC of samples | ≤38 |
Note: Negative Control, Positive Control and IC of samples must be performed correctly, otherwise the sample results is invalid.
Operation details please check from IFU!
MOQ: | We can produce liquid and lyophilized kits |
Price: | USD |
Standard Packaging: | Carton package |
Delivery Period: | Depending on order quantity |
Payment Method: | L/C, T/T, Western Union |
Supply Capacity: | 100,000 per day |
Intended use:
Principle:
Main components:
No. | Components |
BIK-QL-H0019S1
|
1 |
PCR Enzyme Mix
(Lyophilized)
|
24 tests/kit
|
2 |
Positive Control
|
100 μL/tube
|
3 |
Negative Control
|
100 μL/tube
|
4 |
RNase-free water
|
1mL/tube
|
5 |
Paraffin oil
|
1.5mL/tube
|
Specimen requirements:
1. Specimen type
Urine or urethral swabs for men, and female urine, cervical swabs, or vaginal swab samples
2. Specimen Preservation
The specimen can be stored for 3 months at -20±5℃ and for a long time below -70℃
PCR Amplification condition:
PCR amplification according to the following procedures:
Step | Cycle number | Temperature | Time |
1 | 1 | 95℃ | 3min |
2 | 40 | 95℃ | 10s |
60℃ | 30s collect fluorescent |
Instrument detection channel selection: FAM and HEX/VIC.
Quality control:
Ct value | |
Negative Control | No Ct |
Positive Control | ≤30 |
IC of samples | ≤38 |
Note: Negative Control, Positive Control and IC of samples must be performed correctly, otherwise the sample results is invalid.
Operation details please check from IFU!