Intended use:
Principle:
Main components:
No. | Components |
BIK-QL-H0020S1 |
1 |
PCR Enzyme Mix(Lyophilized) |
24tests/kit |
2 | Positive Control | 100 μL/tube |
3 | Negative Control | 100 μL/tube |
4 | RNase-free water | 1mL/tube |
5 |
Paraffin oil |
1.5mL/tube |
Specimen requirements:
1. Specimen type
Urine or female vaginal secretions swab samples.
2. Specimen Preservation
The specimen can be stored for 3 months at -20±5℃ and for a long time below -70℃
PCR Amplification condition:
PCR amplification according to the following procedures:
Step | Cycle number | Temperature | Time |
1 | 1 | 95℃ | 3min |
2 | 40 | 95℃ | 10s |
60℃ | 30s collect fluorescent |
Instrument detection channel selection: FAM and HEX/VIC.
Quality control:
Ct value | |
Negative Control | No Ct |
Positive Control | ≤30 |
IC of samples | ≤38 |
Note: Negative Control, Positive Control and IC of samples must be performed correctly, otherwise the sample results is invalid.
Performance indexes of product:
Operation details please check from IFU!
MOQ: | We can produce liquid and lyophilized kits |
Price: | USD |
Standard Packaging: | Carton package |
Delivery Period: | Depending on order quantity |
Payment Method: | L/C, T/T, Western Union |
Supply Capacity: | 100,000 per day |
Intended use:
Principle:
Main components:
No. | Components |
BIK-QL-H0020S1 |
1 |
PCR Enzyme Mix(Lyophilized) |
24tests/kit |
2 | Positive Control | 100 μL/tube |
3 | Negative Control | 100 μL/tube |
4 | RNase-free water | 1mL/tube |
5 |
Paraffin oil |
1.5mL/tube |
Specimen requirements:
1. Specimen type
Urine or female vaginal secretions swab samples.
2. Specimen Preservation
The specimen can be stored for 3 months at -20±5℃ and for a long time below -70℃
PCR Amplification condition:
PCR amplification according to the following procedures:
Step | Cycle number | Temperature | Time |
1 | 1 | 95℃ | 3min |
2 | 40 | 95℃ | 10s |
60℃ | 30s collect fluorescent |
Instrument detection channel selection: FAM and HEX/VIC.
Quality control:
Ct value | |
Negative Control | No Ct |
Positive Control | ≤30 |
IC of samples | ≤38 |
Note: Negative Control, Positive Control and IC of samples must be performed correctly, otherwise the sample results is invalid.
Performance indexes of product:
Operation details please check from IFU!