Product Details:
|
| Instrument Classification: | Class II | Function: | DNA Extraction, Nucleic Acid Extraction, Diagnostic |
|---|---|---|---|
| Instrument Flux: | 1-32 | Use Consumables: | 12/32/96 Deep Hole Plate |
| Number Of Platform Plates: | 2 | Volume Of Processing: | 50-1000uL |
| Heating Temperature: | At Room Temperature To 140 ºC | Size Of InstrumentSize Of Instrument: | 349 Mm * 325 Mm * 390 Mm |
| Weight: | 25KG | Volatile Mix: | 1-8 Is Adjustable |
| Maximum Stirring Speed: | Bidirectional 10HZ(10 Times Up And Down In 1 Second) | Display: | 13 Inch Color Display |
| Bead Recovery: | 96% | Purification Between The Hole Difference: | CV< 5% |
| Sample Processing Time: | 20-40min(depending On Reagent And Volume Selected) | Program Management: | With New, Edit And Delete Program Functions |
| Data Storage: | Can Store & Gt; 500 Groups Of Program | Extension Mode: | 1 USB Standard Port, Ethernet |
| Power Supply: | 200-240 V100-120:50/60 Hz | Exhaust Way: | Fan |
| Low Noise Processing < 50db: | 50db | ||
| Highlight: | 1000uL Automatic Nucleic Acid Extraction machine ce,25kg Automatic Nucleic Acid Extraction System,25KG Automated DNA RNA Extraction Machine |
||
BioPure series nucleic acid extractor is a set of highly automatic equipment integrating nucleic acid extraction and purification, adopts nano magnetic bead extraction method:
1/BioPure 12 can be used for nucleic acid extraction of 12 samples at a time, and can also be used for nucleic acid extraction of single or multiple samples.
2/BioPure 32 can extract nucleic acid from 32 samples at a time to meet the needs of nucleic acid extraction,
3/BioPure 96 can extract nucleic acids from up to 96 samples.
Specification:
| Instrument flux | 1-32 |
| Number of platform plates | 2 |
| Use consumables | 96 deep hole plate |
| Reagent type | Magnetic bead method open platform |
| volume of processing | 50-1000uL |
| heating temperature | At room temperature to 140 ºC |
| Size of instrument | 349 mm * 325 mm * 390 mm |
| Volatile mix | 1-8 is adjustable |
| Maximum stirring speed | Bidirectional 10HZ(10 times up and down in 1 second) |
| display | 13 inch color display |
| Bead recovery | 96% |
| Purification between the hole difference | CV< 5% |
| Sample processing time | 20-40min(depending on reagent and volume selected) |
| Program management | With new, edit and delete program functions |
| Data storage | Can store & gt; 500 groups of program |
| Extension mode | 1 USB standard port, Ethernet |
| power supply | 200-240 v100-120:50/60 hz |
| Exhaust way | fan |
| weight of the | 25KG |
| Low noise processing < 50db | 50db |
![]()
![]()
![]()